Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.325
Filtrar
1.
Mikrochim Acta ; 191(5): 267, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627300

RESUMO

A ternary hierarchical hybrid Ni@CoxSy/poly(3,4-ethylenedioxythiophene)-reduced graphene oxide (Ni@CoxSy/PEDOT-rGO) is rationally designed and in situ facilely synthesized as electrocatalyst to construct a binder-free sensing platform for non-enzymatic glucose monitoring through traditional electrodeposition procedure. The as-prepared Ni@CoxSy/PEDOT-rGO presents unique hierarchical structure and multiple valence states as well as strong and robust adhesion between Ni@CoxSy/PEDOT-rGO and GCE. Profiting from the aforementioned merits, the sensing platform constructed under optimal conditions achieved a wide detection range (0.2 µM ~ 2.0 mM) with high sensitivity (1546.32 µA cm-2 mM-1), a rapid response time (5 s), an ultralow detection limit (0.094 µM), superior anti-interference performance, excellent reproducibility and considerable stability. Furthermore, the sensor demonstrates an acceptable accuracy and appreciable recoveries ranging from 90.0 to 102.0% with less than 3.98% RSD in human blood serum samples, indicating the prospect of the sensor for the real samples analysis. It will provide a strategy to rationally design and fabricate ternary hierarchical hybrid as nanozyme for glucose assay.


Assuntos
Glicemia , Compostos Bicíclicos Heterocíclicos com Pontes , Cobalto , Grafite , Níquel , Polímeros , Humanos , Níquel/química , Glicemia/análise , Reprodutibilidade dos Testes , Automonitorização da Glicemia , Glucose/análise
2.
Nat Commun ; 15(1): 2828, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565532

RESUMO

Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called 'personalized lag time'. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.


Assuntos
Lentes de Contato Hidrofílicas , Diabetes Mellitus , Animais , Humanos , Glucose/análise , Glicemia , Lágrimas/química , Diabetes Mellitus/diagnóstico
3.
ACS Appl Mater Interfaces ; 16(14): 17219-17231, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38561895

RESUMO

Herein, we demonstrate the detection of glucose in a noninvasive and nonenzymatic manner by utilizing an extended gate field-effect transistor (EGFET) based on the organic molecule pyrene phosphonic acid (PyP4OH8) incorporated nickel metal-organic framework (NiOM-MOF). The prepared electrode responds selectively to glucose instead of sucrose, fructose, maltose, ascorbic acid, and uric acid in a 1× phosphate buffer saline solution. Also, utilizing the scanning Kelvin probe system, the sensing electrode's work function (Φ) is measured to validate the glucose-sensing mechanism. The sensitivity, detection range, response time, limit of detection, and limit of quantification of the electrode are determined to be 24.5 µA mM-1 cm-2, 20 µM to 10 mM, less than 5 s, 2.73 µM, and 8.27 µM, respectively. Most interestingly, the developed electrode follows the Michaelis-Menten kinetics, and the calculated rate constant (km) 0.07 mM indicates a higher affinity of NiOM-MOF toward glucose. The real-time analysis has revealed that the prepared electrode is sensitive to detect glucose in real human saliva, and it can be an alternative device for the noninvasive detection of glucose. Overall, the outcomes of the EGFET studies demonstrate that the prepared electrodes are well-suited for expeditious detection of glucose levels in saliva.


Assuntos
Diabetes Mellitus , Estruturas Metalorgânicas , Humanos , Glucose/análise , Eletrodos , Pirenos
4.
ACS Appl Mater Interfaces ; 16(15): 19605-19614, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38568178

RESUMO

Wearable sweat sensors have received considerable attention due to their great potential for noninvasive continuous monitoring of an individual's health status applications. However, the low secretion rate and fast evaporation of sweat pose challenges in collecting sweat from sedentary individuals for noninvasive analysis of body physiology. Here, we demonstrate wearable textiles for continuous monitoring of sweat at rest using the combination of a heating element and a microfluidic channel to increase localized skin sweat secretion rates and combat sweat evaporation, enabling accurate and stable monitoring of trace amounts of sweat. The Janus sensing yarns with a glucose sensing sensitivity of 36.57 mA cm-2 mM-1 are embroidered into the superhydrophobic heated textile to collect sweat directionally, resulting in improved sweat collection efficiency of up to 96 and 75% retention. The device also maintains a highly durable sensing performance, even in dynamic deformation, recycling, and washing. The microfluidic sensing textile can be further designed into a wireless sensing system that enables sedentary-compatible sweat analysis for the continuous, real-time monitoring of body glucose levels at rest.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Suor/química , Microfluídica , Glucose/análise , Monitorização Fisiológica , Têxteis , Técnicas Biossensoriais/métodos
5.
J Emerg Med ; 66(4): e421-e431, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38462394

RESUMO

BACKGROUND: Hyperkalemia is a common electrolyte abnormality that requires urgent treatment. Insulin is an effective treatment for hyperkalemia, but risk factors for developing insulin-induced hypoglycemia exist (e.g., low pretreatment glucose or renal impairment). OBJECTIVE: This study evaluated the impact of a hyperkalemia protocol tailored to glucose concentration and renal function on insulin-induced hypoglycemia. METHODS: This was a retrospective cohort study of emergency department patients with glucose ≤ 100 mg/dL treated with insulin for hyperkalemia. The primary outcome was incidence of hypoglycemia in patients treated prior to (July 1, 2018-June 30, 2019) vs. after (January 1, 2020-December 31, 2020) the protocol update, which individualized insulin and dextrose doses by glucose concentration and renal function. Secondary outcomes included change in potassium and protocol safety. We assessed factors associated with hypoglycemia using multiple logistic regression. RESULTS: We included 202 total patients (preimplementation: 114, postimplementation: 88). Initial insulin dose was lower in the postimplementation group (p < 0.001). We found a nonsignificant reduction in hypoglycemia in the postimplementation group (42.1% vs. 30.7%, p = 0.10). Degree of potassium reduction was similar in patients who received insulin 5 units vs. 10 units (p = 0.72). Higher pretreatment glucose (log odds ratio [OR] -0.05, 95% confidence interval [CI] -0.08 to -0.02) and additional insulin administration (log OR -1.55, 95% CI -3.01 to -0.25) were associated with reduced risk of developing hypoglycemia. CONCLUSION: A hyperkalemia protocol update was not associated with a significant reduction in hypoglycemia, and the incidence of hypoglycemia remained higher than anticipated. Future studies attempting to optimize treatment in this high-risk population are warranted.


Assuntos
Hiperpotassemia , Hipoglicemia , Insulina , Humanos , Glicemia/análise , Glucose/análise , Hiperpotassemia/tratamento farmacológico , Hipoglicemia/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Insulina/efeitos adversos , Rim , Potássio/sangue , Estudos Retrospectivos
6.
Lab Chip ; 24(7): 2080-2093, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38441218

RESUMO

Pancreatic in vitro research is of major importance to advance mechanistic understanding and development of treatment options for diseases such as diabetes mellitus. We present a thermoplastic-based microphysiological system aiming to model the complex microphysiological structure and function of the endocrine pancreas with concurrent real-time read-out capabilities. The specifically tailored platform enables self-guided trapping of single islets at defined locations: ß-cells are assembled to pseudo-islets and injected into the tissue chamber using hydrostatic pressure-driven flow. The pseudo-islets can further be embedded in an ECM-like hydrogel mimicking the native microenvironment of pancreatic islets in vivo. Non-invasive real-time monitoring of the oxygen levels on-chip is realized by the integration of luminescence-based optical sensors to the platform. To monitor insulin secretion kinetics in response to glucose stimulation in a time-resolved manner, an automated cycling of different glucose conditions is implemented. The model's response to glucose stimulation can be monitored via offline analysis of insulin secretion and via specific changes in oxygen consumption due to higher metabolic activity of pseudo-islets at high glucose levels. To demonstrate applicability for drug testing, the effects of antidiabetic medications are assessed and changes in dynamic insulin secretion are observed in line with the respective mechanism of action. Finally, by integrating human pancreatic islet microtissues, we highlight the flexibility of the platform and demonstrate the preservation of long-term functionality of human endocrine pancreatic tissue.


Assuntos
Insulina , Ilhotas Pancreáticas , Humanos , Insulina/metabolismo , Pâncreas , Glucose/análise , Secreção de Insulina
7.
Talanta ; 273: 125964, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38521022

RESUMO

In this study, Cu-Cu2O/PtPd nanocomposites were synthesized and characterized for their peroxidase-like enzyme activity. X-ray diffraction and energy dispersive X-ray spectroscopy analyses confirmed the successful synthesis of the nanocomposites, which exhibited a flower-like morphology and a more uniform dispersion than Cu-Cu2O. The catalytic activity of Cu-Cu2O/PtPd was evaluated using the chromogenic substrate 3,3',5,5'-tetramethylbenzidine (TMB), finding that Cu-Cu2O/PtPd outperformed Cu-Cu2O. The optimal temperature and pH for the catalytic activity of Cu-Cu2O/PtPd were determined to be 40 °C and pH 4.0, respectively. A kinetic analysis revealed that Cu-Cu2O/PtPd followed Michaelis-Menten kinetics and exhibited a higher affinity toward TMB than the horseradish peroxidase enzyme. The catalytic mechanism of Cu-Cu2O/PtPd involved the generation of hydroxyl radicals, which facilitated the oxidation of TMB. Furthermore, the Cu-Cu2O/PtPd nanocomposite was successfully applied for the colorimetric detection of glucose, demonstrating a linear range of 8-90 µM, a detection limit of 2.389 µM, and high selectivity for glucose over other sugars.


Assuntos
Colorimetria , Glucose , Colorimetria/métodos , Cinética , Glucose/análise , Peroxidase/química , Peroxidases/metabolismo , Peróxido de Hidrogênio/química , Catálise
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 311: 123980, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38335589

RESUMO

Fluorescent copper nanoparticles (CuNPs) was synthesized by one-step chemical reduction method using ascorbic acid (AA) and copper sulfate (CuSO4⋅5H2O) as raw materials, which had good water solubility and fluorescence properties. A green, simple and safe CuNPs@Fe2+ fluorescence probe was developed for the detection of hydrogen peroxide and glucose using Fe2+ as a bridge. The prepared CuNPs could obtain the maximum fluorescence emission wavelength at 440 nm when the excitation wavelength was 360 nm. The average particle size of CuNPs was 10 nm, which had good photobleach resistance, stability and salt tolerance. The fluorescence intensity was quenched due to electron transfer (ET) process when hydrogen peroxide was added to CuNPs@Fe2+ system. This result was mainly because Fenton reaction occured between hydrogen peroxide and Fe2+, producing hydroxyl free radicals (OH) and Fe3+. Since glucose could be catalyzed by specific glucose oxidase (GOX) to produce H2O2 and corresponding oxidation products, the quantitative analysis of glucose was realized when glucose oxidase was introduced into the CuNPs@Fe2+ sensor system. Therefore, a novel CuNPs@Fe2+ fluorescent probe sensor study was constructed to further achieve quantitative detection of H2O2 and glucose. Under the optimized experimental conditions, the linear ranges for H2O2 and glucose were 28.219-171.562 µM and 1.237-75.771 µM, respectively. And the detection limits for H2O2 and glucose were 7.169 µM and 0.540 µM, respectively. In addition, the mechanism of fluorescence probe quenching caused by the interaction between H2O2 and CuNPs@Fe2+ was also discussed. The proposed sensing system had been applied successfully to the detection of glucose in human serum samples.


Assuntos
Glucose , Nanopartículas , Humanos , Glucose/análise , Peróxido de Hidrogênio/análise , Cobre/química , Corantes Fluorescentes/química , Glucose Oxidase , Limite de Detecção
9.
Forensic Sci Int ; 356: 111963, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38354569

RESUMO

The post-mortem diagnosis of hypothermia is challenging to establish due to the lack of pathognomonic findings and the confounding problem that any comorbidity may account for death. A 4-year retrospective case-control study was performed to compare the vitreous glucose and beta-hydroxybutyrate (BHB) concentrations between hypothermia deaths and controls. Over the study period 34 cases of hypothermia and 39 controls were analyzed. Hypothermia deaths versus controls had higher mean vitreous glucose (2.93 mmol/L vs. 1.14 mmol/L; p < 0.0001), BHB (1.89 mmol/L vs. 1.35 mmol/L; p = 0.01), and combined glucose+BHB (4.83 mmol/L vs. 2.46 mmol/L; p < 0.0001). Receiver operating characteristic (ROC) curves showed that the best model for predicting hypothermia in all cases was a combined vitreous glucose+BHB threshold of 2.03 mmol/L (sensitivity 88.2 %; specificity 56.4 %). A sub-group analysis broken down by detectable levels of blood ethanol showed that cases of hypothermia with and without ethanol maintained higher median vitreous glucose relative to the controls (2.05 vs. 0.35 mmol/L and 2.70 vs. 0.65 mmol/L; p = 0.02), however median BHB was only significantly elevated when ethanol was absent (1.88 vs. 1.42 mmol/L; p < 0.0001). Subsequent ROC curve analysis demonstrated that a better model for predicting hypothermia was in cases when blood ethanol was absent. In those deaths vitreous BHB alone had the best area under the curve, with an optimum threshold of 1.83 mmol/L (sensitivity 83.3 %; specificity 96.3 %). This study shows that post-mortem vitreous glucose and BHB are useful ancillary studies to assist in the diagnosis of hypothermia. Ethanol however is a confounder and can alter the utility of vitreous BHB when diagnosing hypothermia in those who have consumed alcohol prior to death.


Assuntos
Glucose , Hipotermia , Humanos , Glucose/análise , Ácido 3-Hidroxibutírico/análise , Estudos Retrospectivos , Estudos de Casos e Controles , Hipotermia/diagnóstico , Etanol/análise
10.
Biotechnol Bioeng ; 121(5): 1688-1701, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38393313

RESUMO

Perfusion cell culture has been gaining increasing popularity for biologics manufacturing due to benefits such as smaller footprint, increased productivity, consistent product quality and manufacturing flexibility, cost savings, and so forth. Process Analytics Technologies tools are highly desirable for effective monitoring and control of long-running perfusion processes. Raman has been widely investigated for monitoring and control of traditional fed batch cell culture process. However, implementation of Raman for perfusion cell culture has been very limited mainly due to challenges with high-cell density and long running times during perfusion which cause extremely high fluorescence interference to Raman spectra and consequently it is exceedingly difficult to develop robust chemometrics models. In this work, a platform based on Raman measurement of permeate has been proposed for effective analysis of perfusion process. It has been demonstrated that this platform can effectively circumvent the fluorescence interference issue while providing rich and timely information about perfusion dynamics to enable efficient process monitoring and robust bioreactor feed control. With the highly consistent spectral data from cell-free sample matrix, development of chemometrics models can be greatly facilitated. Based on this platform, Raman models have been developed for good measurement of several analytes including glucose, lactate, glutamine, glutamate, and permeate titer. Performance of Raman models developed this way has been systematically evaluated and the models have shown good robustness against changes in perfusion scale and variations in permeate flowrate; thus models developed from small lab scale can be directly transferred for implementation in much larger scale of perfusion. With demonstrated robustness, this platform provides a reliable approach for automated glucose feed control in perfusion bioreactors. Glucose model developed from small lab scale has been successfully implemented for automated continuous glucose feed control of perfusion cell culture at much larger scale.


Assuntos
Técnicas de Cultura Celular por Lotes , Reatores Biológicos , Cricetinae , Animais , Cricetulus , Células CHO , Perfusão , Glucose/análise , Análise Espectral Raman
11.
Int J Biol Macromol ; 262(Pt 1): 130006, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38331067

RESUMO

The processing characteristics of yogurt are closely related to the composition and arrangement of exopolysaccharides (EPS) in lactic acid bacteria (LAB). To fully understand and develop the functional properties of EPS and to study the effect of EPS molecular weight on yogurt and its mechanism, the physicochemical properties of high molecular weight EPS-LH43, medium molecular weight EPS-LH13, and low molecular weight EPS-LH23, as well as the gel properties and protein conformation of yogurt, were determined and analyzed in this experiment. The results indicate that EPS-LH43 and EPS-LH13 are both composed of mannose, rhamnose, galacturonic acid, glucose, and galactose. EPS-LH23 is composed of mannose, galacturonic acid, glucose, and galactose. Their Number-average Molecular Weight is 5.21 × 106 Da, 2.39 × 106 Da and 3.76 × 105 Da, respectively. In addition, all three types of EPS have good thermal stability and can improve the stability of casein. In addition, the analysis of the texture, particle size, potential, water holding capacity, rheology, low field nuclear magnetic resonance, microstructure, and flavor characteristics of yogurt confirmed the relationship between the molecular weight of LAB EPS and the gel properties of yogurt. Fluorescence spectrophotometer and circular dichroism analysis indicate that the different molecular weights of LAB EPS have different effects on protein structure, which is an intrinsic factor leading to significant differences in the gel properties of the three types of fermented milk. These findings provide new references for enhancing the understanding of the structure-activity relationship of EPS and indicate that EPS-LH43 can be used to improve the gel properties of dairy products.


Assuntos
Ácidos Hexurônicos , Lactobacillus helveticus , Iogurte , Iogurte/microbiologia , Polissacarídeos Bacterianos/química , Peso Molecular , Galactose/análise , Manose , Glucose/análise , Fermentação
12.
Analyst ; 149(6): 1719-1726, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38334484

RESUMO

Glucose is an important biomarker for diagnosing and prognosing various diseases, including diabetes and hypoglycemia, which can have severe side effects, symptoms, and even lead to death in patients. As a result, there is a need for quick and economical glucose level measurements to help identify those at potential risk. With the increase in smartphone users, portable smartphone glucose sensors are becoming popular. In this paper, we present a disposable microfluidic glucose sensor that accurately and rapidly quantifies glucose levels in human urine using a combination of colorimetric analysis and computer vision. This glucose sensor implements a disposable microfluidic device based on medical-grade tapes and glucose analysis strips on a glass slide integrated with a custom-made polydimethylsiloxane (PDMS) micropump that accelerates capillary flow, making it economical, convenient, rapid, and equipment-free. After absorbing the target solution, the disposable device is slid into the 3D-printed main chassis and illuminated exclusively with Light Emitting Diode (LED) illumination, which is pivotal to color-sensitive experiments. After collecting images, the images are imported into the algorithm to measure the glucose levels using computer vision and average RGB values measurements. This article illustrates the impressive accuracy and consistency of the glucose sensor in quantifying glucose in sucrose water. This is evidenced by the close agreement between the computer vision method used by the sensor and the traditional method of measuring in the biology field, as well as the small variation observed between different sensor performances. The exponential regression curve used in the study further confirms the strong relationship between glucose concentrations and average RGB values, with an R-square value of 0.997 indicating a high degree of correlation between these variables. The article also emphasizes the potential transferability of the solution described to other types of assays and smartphone-based sensors.


Assuntos
Diabetes Mellitus , Smartphone , Humanos , Microfluídica , Glucose/análise , Diabetes Mellitus/diagnóstico
13.
Nanotechnology ; 35(17)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334120

RESUMO

Here, we demonstrate hydrothermally grown bismuth sulfide (Bi2S3) micro flowers decorated nickel foam (NF) for electrochemical detection of melamine in bottled milk samples. The orthorhombic phase of hydrothermally grown Bi2S3is confirmed by the detailed characterization of x-ray diffraction and its high surface area micro flowers-like morphology is investigated via field emission scanning electron microscope. Furthermore, the surface chemical oxidation state and binding energy of Bi2S3/NF micro flowers is analyzed by x-ray photoelectron spectroscopy studies. The sensor exhibits a wide linear range of detection from 10 ng l-1to 1 mg l-1and a superior sensitivity of 3.4 mA cm-2to melamine using differential pulse voltammetry technique, with a lower limit of detection (7.1 ng l-1). The as-fabricated sensor is highly selective against interfering species of p-phenylenediamine (PPDA), cyanuric acid (CA), aniline, ascorbic acid, glucose (Glu), and calcium ion (Ca2+). Real-time analysis done in milk by the standard addition method shows an excellent recovery percentage of Ì´ 98%. The sensor's electrochemical mechanism studies reveal that the high surface area bismuth sulfide micro flowers surface interacts strongly with melamine molecules through hydrogen bonding and van der Waals forces, resulting in a significant change in the sensor's electrical properties while 3D skeletal Nickel foam as a substrate provides stability, enhances its catalytic activity by providing a more number /of active sites and facilitates rapid electron transfer. The work presented here confirms Bi2S3/NF as a high-performance electrode that can be used for the detection of other biomolecules used in clinical diagnosis and biomedical research.


Assuntos
Bismuto , Leite , Níquel , Sulfetos , Triazinas , Animais , Níquel/química , Leite/química , Glucose/análise , Técnicas Eletroquímicas
14.
Int J Biol Macromol ; 260(Pt 2): 129171, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38171437

RESUMO

"Nine Steaming Nine Sun-Drying" Polygonti rhizome has been used as valuable tonic health-care products for thousands of years. This research aimed to determine the correlations between the structure and anti-diabetic activities of three novel polysaccharides isolated from the raw and "Nine Steaming Nine Sun-Drying" Polygonti rhizome, with PRP-R from the raw ones and PRP-9Z and PRP-9A from the steamed ones. Structures of the isolated polysaccharides were determined by IR and NMR spectra, as well as monosaccharide composition and methylation analysis. In vitro assays indicated that PRP-9Z could improve the glucose consumptions more effectively than PRP-R and PRP-9A via Akt/GSK3ß insulin signal pathway by western blotting analysis. In vivo assays indicated PRP-9Z could improve the glucose tolerance in the BKS-db mice. Histopathological assay demonstrated that PRP-9Z effectively reduced the damage of the kidney and liver. The above results indicated that PRP-9Z from "Nine Steaming Nine Sun-Drying" Polygonti rhizome showed significant anti-diabetic properties, which indicated that PRP-9Z with higher content of →1)-ß-Frup-(2→ was more active than PRP-R with higher →1,6)-ß-Fruf-(2→ and PRP-9A with higher →4)-ß-Galp(1→.


Assuntos
Polissacarídeos , Rizoma , Animais , Camundongos , Rizoma/química , Polissacarídeos/química , Vapor , Extratos Vegetais/química , Glucose/análise
15.
Int J Biol Macromol ; 261(Pt 2): 129793, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38290627

RESUMO

A water-soluble glycopeptide (named GL-PWQ3) with a molecular weight (Mw) of 2.40 × 104 g/mol was isolated from Ganoderma lucidum fruiting body by hot water extraction, membrane ultrafiltration, and gel column chromatography, which mainly consisted of glucose and galactose. Based on the methylation, FT-IR, 1D, and 2D NMR analysis, the polysaccharide portion of GL-PWQ3 was identified as a glucogalactan, which was comprised of unsubstituted (1,6-α-Galp, 1,6-ß-Glcp, 1,4-ß-Glcp) and monosubstituted (1,2,6-α-Galp and 1,3,6-ß-Glcp) in the backbone and possible branches that at the O-3 position of 1,3-Glcp and T-Glcp, and the O-2 position of T-Fucp, T-Manp or T-Glcp. The chain conformational study by SEC-MALLS-RI and AFM revealed that GL-PWQ3 was identified as a highly branched polysaccharide with a polydispersity index of 1.25, and might have compact sphere structures caused by stacked multiple chains. Moreover, the GL-PWQ3 shows strong anti-oxidative activity in NRK-52E cells. This study provides a theoretical basis for further elucidating the structure-functionality relationships of GL-PWQ3 and its potential application as a natural antioxidant in pharmacotherapy as well as functional food additives.


Assuntos
Reishi , Reishi/química , Espectroscopia de Infravermelho com Transformada de Fourier , Polissacarídeos/química , Glucose/análise , Peso Molecular , Água
16.
J Colloid Interface Sci ; 659: 718-727, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38211489

RESUMO

Herein, we present a novel microwave-assisted method for the synthesis of palladium nanoparticles (PdNPs) supported by Limonia acidissima Groff tree extract gum. The synthesized PdNPs were characterized using various analytical techniques, including FTIR, SEM, TEM, UV-visible, and powder XRD analyses. TEM and XRD analysis confirmed that the synthesized LAG-PdNPs are highly crystalline nature spherical shapes with an average size diameter of 7-9 nm. We employed these gum-capped PdNPs to investigate their peroxidase-like activity for colorimetric detection of hydrogen peroxide (H2O2) and glucose. The oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2, catalyzed by PdNPs, produces oxidation products quantified at 652 nm using spectrophotometry. The catalytic activity of PdNPs was optimized with respect to temperature and pH. The developed method exhibited a linear range of detection from 1 to 50 µm, with detection limits of 0.35 µm for H2O2 and 0.60 µm for glucose.


Assuntos
Colorimetria , Nanopartículas Metálicas , Nanopartículas Metálicas/química , Paládio/química , Peróxido de Hidrogênio/análise , Micro-Ondas , Glucose/análise
17.
Biosens Bioelectron ; 248: 115896, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38176252

RESUMO

A common challenge in microfluidic cell cultures has to do with analysis of cell function without replacing a significant fraction of the culture volume and disturbing local concentration gradients of signals. To address this challenge, we developed a microfluidic cell culture device with an integrated bioanalysis unit to enable on-chip analysis of picoliter volumes of cell-conditioned media. The culture module consisted of an array of 140 microwells with a diameter of 300 m which were made low-binding to promote organization of cells into 3D spheroids. The bioanalysis module contained a droplet generator unit, 15 micromechanical valves and reservoirs loaded with reagents. Each 0.8 nL droplet contained an aliquot of conditioned media mixed with assay reagents. The use of microvalves allowed us to load enzymatic assay and immunoassay into sequentially generated droplets for detection of glucose and albumin, respectively. As a biological application of the microfluidic device, we evaluated hormonal stimulation and glucose consumption of hepatic spheroids. To mimic physiological processes occurring during feeding and fasting, hepatic spheroids were exposed to pancreatic hormones, insulin or glucagon. The droplet-based bioanalysis module was used to measure uptake or release of glucose upon hormonal stimulation. In the future, we intend to use this microfluidic device to mimic and measure pathophysiological processes associated with hepatic insulin resistance and diabetes in the context of metabolic syndrome.


Assuntos
Técnicas Biossensoriais , Técnicas Analíticas Microfluídicas , Microfluídica , Meios de Cultivo Condicionados , Glucose/análise
18.
Lab Chip ; 24(4): 776-786, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38197467

RESUMO

Thread-based microfluidic colorimetric sensors have been deemed a potential tool that may be incorporated into textiles for non-invasive sweat analysis. Nevertheless, their poor performance significantly limits their practical uses in sweat glucose detection down to 20 µM. Herein, a microfluidic glucose sensing device containing a salt-responsive thread is developed for the highly sensitive detection of glucose in human sweat. By grafting a zwitterionic polymer brush-which could react to ionic strength by changing the conformation of the polymer chains from the collapsing state to the stretching state-onto the cotton thread, the salt-responsive thread was created. Compared to the pristine cotton thread, the modified thread has better ion-capture capabilities, a more noticeable swelling effect, and a higher ability to absorb water. These enable a significant enrichment of glucose when the saline solution passes through it. The salt-responsive thread was employed to construct a thread/paper-based microfluidic sensing device for the monitoring of glucose in artificial sweat, exhibiting a sensitivity of -0.255 µM-1 and a detection limit of 14.7 µM. In comparison to the pristine cotton thread-based device, the performance is significantly superior. Using a hydrophobic fabric and salt-responsive threads, a glucose-sensing headband was prepared for on-body sweat glucose monitoring. With the use of a smartphone-based image analysis system, the headband can detect the concentration of glucose in a volunteer's perspiration. Using the thread-based salt-responsive zwitterionic polymer brush might offer a novel approach to creating wearable sweat sensors with extremely high sensitivity.


Assuntos
Técnicas Biossensoriais , Suor , Humanos , Suor/química , Microfluídica , Automonitorização da Glicemia , Glicemia/análise , Glucose/análise , Polímeros
19.
Ultrason Sonochem ; 103: 106784, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38295744

RESUMO

The present study aimed to analyze and establish an effective combination of ultrasound and immersion pretreatment processes for drying Taikor (Garcinia pendunculata Roxb.) fruits. Taikorslices were first immersed in 10 % sucrose, fructose, and glucose solution. Then, the immersed slices were treated in an ultrasonic bath at 30 °C for 10, 20, and 30 min. Drying operations were carried out at 50, 60, and 70 °C, with a fixed relative humidity of 30 %. The Page, Newton, Henderson and Pabis, and Weibull distribution models were fitted to the obtained drying data to determine the best kinetic model that effectively describes the drying properties ofTaikor. After drying operations, changes in quality parameters, e.g., ß-carotene, vitamin C, B vitamins, color, antioxidant activities, and microbial loads, were measured to obtain the best drying temperature and the most effective pretreatment combination with minimum loss of nutrients of the sample. Among different kinetic models, both Page and Weibull distribution models showed the best R2 values of 0.9867 and 0.9366, respectively. The chemical properties were preserved to the greatest extent possible by drying at 50 °C with glucose pretreatment. The color parameters were better preserved by fructose pretreatment. Sonication time also had profound effect on the quality parameters of dried Taikor slices. However, higher temperature drying required a shorter time for drying and exhibited better performance in microbial load reduction. This study's findings will help to establish an effective drying condition forGarcinia pedunculatafruits.


Assuntos
Frutas , Thoracica , Animais , Frutas/química , Antioxidantes/análise , Vitaminas/análise , Dessecação , Frutose/análise , Glucose/análise
20.
Anal Chim Acta ; 1288: 342148, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38220282

RESUMO

Long-term high blood glucose levels brings extremely detrimental effect on diabetic patients, such as blindness, renal failure, and cardiovascular diseases. Therefore, there is an urgent need to develop highly flexible and sensitive sensors for precisely non-invasive and continuous monitoring glucose levels. Herein, we present a highly flexible and sensitive wearable sensor for non-enzymatic electrochemical glucose analysis with vertically aligned mushroom-like gold nanowires (v-AuNWs) chemically grown on stainless steel wire sieve (SSWS) as integrated electrode. Owing to the unique nanostructures and excellent catalysis of the v-AuNWs, the as-fabricated glucose sensors exhibit superior flexibility and excellent electro-catalytic capability. In detail, these sensors display rapid response towards glucose within 5 s, and the sensor constructed with v-AuNWs for growth time of 15 min shows the highest sensitivity of 180.1 µA mM-1 cm-2 within a wide linear range of 6.5 × 10-4 mM-12.0 mM and the lowest detection limit of 0.65 µM (S/N = 3). It is noteworthy that due to the good ductility of the v-AuNWs and their strong contact with the SSWS substrate, these glucose sensors exhibit no obvious response variation after repeated bending for 100 times at bending angle of 180°. Additionally, the glucose sensors display superior anti-interfering capability as well as desirable repeatability. More importantly, these glucose sensors can be attached on human skin to determine sweat glucose reliably and analyze glucose concentration in human serum in vitro.


Assuntos
Técnicas Biossensoriais , Nanofios , Dispositivos Eletrônicos Vestíveis , Humanos , Nanofios/química , Ouro/química , Aço Inoxidável , Glucose/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...